CRD02
Filtration System CRD02
Filter Area 0.2 m²
CRD filtration is based on the use of disc-shaped rotating bodies, employing a special process to enable dynamic cross-flow filtration. CRD systems are primarily used for laboratory experiments or small-scale applications, particularly suitable for filtering highly viscous liquids and separating particles that are challenging to remove.
Dynamic Cross Flow Filtration is a state-of-the-art filtration technology used in various industries such as food, chemical, pharmaceutical, and biotech. It allows for precise and efficient separation of solids and liquids. These filtration systems are capable of effectively removing particles or proteins of different sizes.
The technology enables continuous filtration and can effectively remove a variety of particle sizes, achieving concentration and purification of products that are not only high-quality but also cost-effective.
novoflow GmbH is a global leader in Dynamic Cross Flow Filtration, offering a wide range of solutions for various applications. Our experts assist you in selecting the right equipment and solutions, providing support during installation and commissioning. We take pride in taking a pioneering role in Dynamic Cross Flow Filtration with our expertise and commitment to quality and customer service.
Haven't found the right filtration system yet? Configure your customized Dynamic Cross Flow Filtration system with our assistance!
Test ... Rent ... Purchase!
Advantages
- Plug and play!
- Compact filter system
- Initial feasibility tests or small production volumes
- Special designs, e.g. with double jacket, reduced volume or special seals
- Glass lid with quick-release fastener
- Various pore sizes: 3 nm, 5 nm, 10 nm, 50 nm, 70 nm, 100 nm, 200 nm, 0.4 µm, 0.8 µm and 1.1 µm
- Switch cabinet with logo control, for simple parameter settings
- Rotation speed freely adjustable
- Filtration pressure (TMD): up to 4 bar, freely adjustable
- Baffle for additional turbulence
- Automatic backwash unit
- Freely selectable backwash pressure
- Feed and backwash pump already integrated
Filter area | 0.2 m² |
---|---|
Filter discs | 152 mm ceramic |
Pore sizes | 3 nm, 5 nm, 10 nm, 50 nm, 70 nm, 100 nm, 200 nm, 0.4 µm, 0.8 µm and 1.1 µm |
Number of filter discs | 6 |
Connections inflow | 17.2 Clamp DIN 32676 Series B |
Connections overflow | 13.5 Clamp DIN 32676 Series B |
Connections filtrate | 13.5 Clamp DIN 32676 Series B |
Volumen | approx. 4 L |
Operating pressure | 0 - 4 bar * |
Pressure backwash | 0 - 2.5 bar |
Temperature | 5 - 60 °C ** |
ph range microfiltration *** | 0 - 12 pH (max. 40°C) I 0 - 13 pH (max. 50°C) |
ph range ultrafiltration *** | 1 - 12 pH (max. 40°C) I 1 - 13 pH (max. 40°C) |
Speed | 100 - 1250 rpm |
Pump type | Compressed Air Diaphragm Pump |
Pump capacity | 5 - 17 L/min |
Connection voltage | 230 V / 50 Hz |
Electrical power | 750 watts |
Control | Siemens Logo |
Dimensions | 650 x 280 x 700 mm |
Weight | 72 kg |
Control cabinet dimensions | 450 x 230 x 300 mm |
Weight | 13.6 kg |